Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Anal Chim Acta ; 1301: 342387, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38553114

RESUMO

BACKGROUND: Parallel artificial liquid membrane extraction (PALME) is a 96-well plate setup variant of liquid-phase microextraction. Basic or acidic analytes are extracted in neutral form from the sample, through a supported liquid membrane (SLM), and into aqueous acceptor. PALME is already considered a green extraction technique, but in the current conceptual work, we sought to make it even greener by replacing the use of organic solvents with essential oils (EO). PALME was combined with LC-MS/MS for analysis of plasma samples and multiple drugs of abuse with toxicological relevance (amphetamines, phenethylamines, synthetic cathinones, designer benzodiazepines, ayahuasca alkaloids, lysergic acid diethylamide, and ketamine). RESULTS: Fourteen EO were compared to organic solvents frequently used in PALME. The EO termed smart & sassy yielded the best analyte recovery for all drugs studied and was thus selected as SLM. Then, factorial screening and Box-Behnken were employed to optimize the technique. The extraction time, concentration of base, sample volume, and percentage of trioctylamine significantly impacted analyte recovery. The optimum values were defined as 120 min, 10 mmol/L of NaOH, 150 µL, and 0%, respectively. Once optimized, validation parameters were 1-100 ng mL-1 as linear range, accuracy ±16.4%, precision >83%, 1 ng mL-1 as limit of quantitation, 0.1-0.75 ng mL-1 as limit of detection, matrix effect <20%, and recovery 20-106%. Additionally, EO purchased from different production batches were tested and achieved acceptable reproducibility. Data were in compliance with requirements set by internationally accepted validation guidelines and the applicability of the technique was proven using authentic samples. SIGNIFICANCE: In this study, the use of an EO provided a solvent-free sample preparation technique suited to extract different classes of drugs of abuse from plasma samples, dismissing the use of hazardous organic solvents. The method also provided excellent sample clean-up, thus being a simple and efficient tool for toxicological applications that is in agreement with the principles of sustainable chemistry.


Assuntos
60705 , Microextração em Fase Líquida , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Membranas Artificiais , Reprodutibilidade dos Testes , Solventes , Limite de Detecção
2.
J Anal Toxicol ; 47(9): 787-796, 2023 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-37700512

RESUMO

Benzimidazole opioids, often referred to as nitazenes, represent a subgroup of new psychoactive substances with a recent increase in fatal overdoses in the USA and Europe. With a variety of analogs emerging on the illicit drug market, forensic laboratories are challenged to identify these potent drugs. We here present a simple quantitative approach for the determination of nine nitazene analogs, namely, clonitazene, etodesnitazene, etonitazene, etonitazepyne, flunitazene, isotonitazene, metodesnitazene, metonitazene and protonitazene in whole blood using liquid-phase microextraction and electromembrane extraction in a 96-well format and liquid chromatography-tandem mass spectrometry. Green and efficient sample preparation was accomplished by liquid-phase microextraction in a 96-well format and resulted in high extraction yields for all analytes (>81%). Here, blood diluted with buffer (1:1, %v) was extracted from a donor compartment across a thin organic liquid membrane and into an aqueous acceptor solution. The acceptor solution was collected and directly injected into the analysis platform. Chromatographic separation was accomplished with a biphenyl column, allowing for a baseline separation of the structural isomers isotonitazene and protonitazene before detection by multiple reaction monitoring. Validation was performed according to Scientific Working Group of Forensic Toxicology guidelines. The calibration range was from 0.5 to 50 nM (except for protonitazene and clonitazene from 0.1 nM) with good linearity and limits of detection down to 0.01 nM. An AGREEprep assessment was performed to evaluate sample preparation greenness, with a final score of 0.71. Nitazenes represent a current threat to public health, and analytical methods that cover a wide range of these analogs are limited. Here, the described method may assist in the detection of nitazenes in whole blood and prevent these substances from being missed in postmortem investigations.


Assuntos
Drogas Ilícitas , Espectrometria de Massas em Tandem , Espectrometria de Massas em Tandem/métodos , Analgésicos Opioides , Cromatografia Líquida de Alta Pressão/métodos , Drogas Ilícitas/análise , Benzimidazóis
4.
Anal Bioanal Chem ; 415(22): 5323-5335, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37386201

RESUMO

The use of oral fluid as sample matrix has gained significance in the analysis of drugs of abuse due to its non-invasive nature. In this study, the 13 opioids morphine, oxycodone, codeine, O-desmethyl tramadol, ethylmorphine, tramadol, pethidine, ketobemidone, buprenorphine, fentanyl, cyclopropylfentanyl, etonitazepyne, and methadone were extracted from oral fluid using electromembrane extraction based on conductive vials prior to analysis with ultra-high performance liquid chromatography-tandem mass spectrometry. Oral fluid was collected using Quantisal collection kits. By applying voltage, target analytes were extracted from oral fluid samples diluted with 0.1% formic acid, across a liquid membrane and into a 300 µL 0.1% (v/v) formic acid solution. The liquid membrane comprised 8 µL membrane solvent immobilized in the pores of a flat porous polypropylene membrane. The membrane solvent was a mixture of 6-methylcoumarin, thymol, and 2-nitrophenyloctyl ether. The composition of the membrane solvent was found to be the most important parameter to achieve simultaneous extraction of all target opioids, which had predicted log P values in the range from 0.7 to 5.0. The method was validated in accordance to the guidelines by the European Medical Agency with satisfactory results. Intra- and inter-day precision and bias were within guideline limits of ± 15% for 12 of 13 compounds. Extraction recoveries ranged from 39 to 104% (CV ≤ 23%). Internal standard normalized matrix effects were in the range from 88 to 103% (CV ≤ 5%). Quantitative results of authentic oral fluid samples were in accordance with a routine screening method, and external quality control samples for both hydrophilic and lipophilic compounds were within acceptable limits.


Assuntos
Analgésicos Opioides , Tramadol , Analgésicos Opioides/análise , Formiatos , Cromatografia Líquida de Alta Pressão/métodos , Solventes
5.
Drug Test Anal ; 15(8): 909-918, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37114617

RESUMO

Separation and quantification of amphetamine enantiomers are commonly used to distinguish between consumption of prescription amphetamine (mostly S-amphetamine) and illicit forms of the drug (racemate). In this study, electromembrane extraction with prototype conductive vials was combined with ultra-high performance supercritical fluid chromatography (UHPSFC-MS/MS) to quantify R- and S-amphetamine in urine. Amphetamine was extracted from 100 µL urine, diluted with 25 µL internal standard solution and 175 µL 130 mM formic acid, across a supported liquid membrane (SLM) consisting of 9 µL of a 1:1(w/w) mixture of 2-nitrophenyloctyl ether (NPOE) and bis(2-ethylhexyl)phosphite (DEHPi) into an acceptor phase containing 300 µL 130 mM formic acid. The extraction was facilitated by the application of 30 V for 15 min. Enantiomeric separation was achieved using UHPSFC-MS/MS with a chiral stationary phase. The calibration range was 50-10,000 ng/mL for each enantiomer. The between-assay CV was ≤5%, within-assay CV ≤ 1.5%, and bias within ±2%. Recoveries were 83%-90% (CV ≤ 6%), and internal standard corrected matrix effects were 99-105 (CV ≤ 2%). The matrix effects ranged from 96% to 98% (CV ≤ 8%) when not corrected by the internal standard. The EME method was compared with a chiral routine method that employed liquid-liquid extraction (LLE) for sample preparation. Assay results were in agreement with the routine method, and the mean deviation between methods was 3%, ranging from -21% to 31%. Finally, sample preparation greenness was assessed using the AGREEprep tool, which resulted in a greenness score of 0.54 for conductive vial EME, opposed to 0.47 for semi-automated 96-well LLE.


Assuntos
Anfetamina , Cromatografia com Fluido Supercrítico , Anfetamina/química , Espectrometria de Massas em Tandem/métodos , Cromatografia com Fluido Supercrítico/métodos , Formiatos , Cromatografia Líquida de Alta Pressão/métodos
6.
J Anal Toxicol ; 47(3): 287-298, 2023 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-36542823

RESUMO

Benzodiazepines and z-hypnotics are detected in the majority of fatal overdose cases in Norway, often in combination with other drugs of abuse, and their concentrations in peripheral blood (PB) might be important to elucidate the cause of death. In some forensic autopsies, PB is however not available. The aim of the present study was to compare concentrations of benzodiazepines and z-hypnotics in five alternative matrices to assess whether these concentrations are comparable to concentrations in PB. A total of 109 forensic autopsy cases were included. PB, cardiac blood (CB), pericardial fluid (PF), psoas muscle (PM), lateral vastus muscle (LVM) and vitreous humor (VH) from each case were analyzed using ultra high performance liquid chromatography--tandem mass spectrometry. We were able to detect clonazepam, 7-aminoclonazepam, flunitrazepam, 7-aminoflunitrazepam, nitrazepam, 7-aminonitrazepam, diazepam, nordiazepam, oxazepam, alprazolam, midazolam, zopiclone and zolpidem in all the analyzed matrices. Concentrations measured in VH were generally much lower than those of PB for all compounds except zopiclone. 7-Amino metabolite concentrations were high compared to the parent compounds, although less so for the muscle samples. Concentrations of the parent nitrobenzodiazepines in muscles were higher than those in PB, but for the other compounds, concentrations in muscle showed good correspondence with PB. Both CB and PF were viable alternative matrices for PB, although a larger variation and a tendency for higher concentrations in PF were observed. This study shows that CB, PM, LVM and PF can give comparable concentrations to PB for benzodiazepines and z-hypnotics, while VH was less suitable. The concentrations in alternative matrices must, however, be interpreted carefully.


Assuntos
Benzodiazepinas , Hipnóticos e Sedativos , Autopsia , Compostos Azabicíclicos
7.
J Chromatogr A ; 1664: 462769, 2022 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-34998024

RESUMO

The present paper defines the optimal extraction window (OEW) for three-phase membrane-based liquid-phase microextraction (MP-LPME) in terms of analyte polarity (log P), and anchors this to existing theories for equilibrium partitioning and kinetics. Using deep eutectic solvents (DES) as supported liquid membranes (SLM), we investigated how the OEW was affected by ionic-, hydrogen bond and π-π interactions between the SLM and analyte. Eleven basic model analytes in the range -0.4 < log P < 5.0 were extracted by MB-LPME in a 96-well format. Extraction was performed from 250 µL standard solution in 25 mM phosphate buffer (pH 7.0) into 50 µL of 10 mM HCl acceptor solution (pH 2.0) with mixtures of coumarin, camphor, DL-menthol, and thymol, with and without the ionic carrier di(2-ethylhexyl) phosphate (DEHP), as the SLM. The OEW with pure DES was in the range 2 < log P < 5, and low SLM aromaticity was favorable for the extraction of non-polar analytes. Here, extraction recoveries up to 98% were obtained. Upon addition of DEHP to the SLMs, the OEW shifted to the range -0.5 < log P < 2, and a combination of 5% DEHP and moderate aromaticity resulted in extraction recoveries up to 80% for the polar analytes. Extraction with ionic carrier was inefficient for the non-polar analytes, due to excessive trapping in the SLM. The results from our study show that LPME performs optimally in a relatively narrow log P-window of ≈ 2-3 units and that the OEW is primarily affected by ionic carrier and aromaticity.


Assuntos
Microextração em Fase Líquida , Preparações Farmacêuticas , Solventes Eutéticos Profundos , Cinética , Membranas Artificiais
8.
Forensic Sci Int ; 329: 111082, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34775328

RESUMO

Cannabis is the most widely used illicit substance worldwide. A limited number of studies have investigated whether tetrahydrocannabinol (THC) and cannabidiol (CBD) can be detected in other postmortem matrices than blood and urine. The aim of this study was to investigate the distribution of THC and CBD in several different postmortem matrices. Concentrations in peripheral blood were compared to those in cardiac blood, pericardial fluid, psoas muscle, vastus lateralis muscle, and vitreous humor. A total of 39 postmortem forensic autopsy cases were included. THC and CBD were analyzed using gas chromatography-mass spectrometry. We were able to detect both THC and CBD in most of the analyzed matrices. For vitreous humor, however, only approximately 50% of the cases were available for analysis, and only two were found to be positive. Median concentrations in peripheral blood were 0.0040 (0.00042-0.056) mg/L for THC and 0.0013 (0-0.023) mg/L for CBD. The concentration ratios between pericardial fluid and cardiac blood compared to peripheral blood were< 1 for both THC and CBD for the majority of the cases. For THC, a median ratio of 0.60 (0.063-7.2) and 0.65 (0.068-4.8) were found for pericardial fluid and cardiac blood, respectively, compared to peripheral blood, whereas for CBD the corresponding median ratios were 0.40 (0.010-1.9) and 0.80 (0.017-2.4). The THC concentrations in psoas muscle and vastus lateralis muscle were high compared to those in peripheral blood in several cases, and large variations in the muscles to peripheral blood concentration ratios were seen. This was also the case for CBD. Our study shows that THC and CBD can be detected in postmortem matrices other than peripheral blood, and results from other matrices might provide important information in forensic cases where peripheral blood is not available. However, vitreous humor was not suitable for detecting neither THC nor CBD.


Assuntos
Canabidiol , Cannabis , Detecção do Abuso de Substâncias , Autopsia , Dronabinol
9.
Artigo em Inglês | MEDLINE | ID: mdl-34624684

RESUMO

Conductive vial electromembrane extraction (EME) with prototype equipment was applied for the first time to extract lipophilic basic drugs from serum. With this equipment, traditional platinum electrodes were replaced with sample and acceptor vials made from a conductive polymer, making the electrodes fully integrated and disposable. EME was combined with UHPLC-MS/MS, and a method to determine selected psychoactive drugs (alimemazine, amitriptyline, atomoxetine, clomipramine, doxepin, duloxetine, fluvoxamine, levomepromazine, nortriptyline and trimipramine) and metabolites (desmethyl clomipramine and desmethyl doxepin) in serum was developed, optimized, and validated. Extractions were carried out with 50 V for 15 min from serum samples (100 µL) diluted 1:3 with formic acid (0.1% v/v), using 2-nitrophenyl octyl ether as the supported liquid membrane (SLM), and formic acid (0.1% v/v, 300 µL) as acceptor phase. Using conductive vial EME, the extraction of lipophilic drugs reached exhaustive or near-exhaustive conditions, with recoveries in the range 75-117%. The method demonstrated excellent accuracy and precision, with bias within ± 6%, and intra- and inter-day CVs ranging 0.9 - 6% and 2 - 6%, respectively. In addition, acceptor phases were completely free of glycerophosphocholines. EME-UHPLC-MS/MS was successfully applied in determination of psychoactive drugs in 30 patient samples, and the results were in agreement with the current hospital routine method at St. Olav University Hospital (Trondheim, Norway). Obtaining comparable results to well-established routine methods is highly important for future implementation of EME into routine laboratories. These results thus serve as motivation for further advancing the EME technology. Until now, EME has been carried out with laboratory-build equipment, and the introduction of commercially available standardized equipment is expected to have a positive impact on future research activity.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Técnicas Eletroquímicas/métodos , Psicotrópicos/sangue , Espectrometria de Massas em Tandem/métodos , Humanos , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes
10.
Talanta ; 223(Pt 2): 121748, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33298272

RESUMO

Electromembrane extraction (EME) of the polar zwitterionic drugs, anthracyclines (ANT, doxorubicin, daunorubicin and its metabolite daunorubicinol), from rabbit plasma was investigated. The optimized EME was compared to conventional sample pretreatment techniques such as protein precipitation (PP) and liquid-liquid extraction (LLE), mainly in terms of extraction reliability, recovery and matrix effect. In addition, phospholipids profile in the individual extracts was evaluated. The extracted samples were analyzed using UHPLC-MS/MS with electrospray ionization in positive ion mode. The method was validated within the concentration range of 0.25-1000 ng/mL for all tested ANT. Compared with PP and LLE, the EME provided high extraction recovery (more than 80% for all ANT) and excellent sample clean-up (matrix effect were 100 ± 10% with RSD values lower than 4% for all ANT). Furthermore, only negligible amounts of phospholipids were detected in the EME samples. Finally, practical applicability of EME was proved by analysis of plasma samples taken from a pilot in vivo study in rabbits. Consistent results were obtained when using both EME and LLE to extract the plasma prior to the analysis, which further confirmed high reliability of EME. This study clearly showed that EME is a simple, rapid, repeatable technique for extraction of ANT from plasma and it is an up to date alternative to routine conventional extraction techniques.


Assuntos
Preparações Farmacêuticas , Espectrometria de Massas em Tandem , Animais , Antraciclinas , Membranas Artificiais , Coelhos , Reprodutibilidade dos Testes
11.
J Pharm Biomed Anal ; 189: 113446, 2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-32619730

RESUMO

In this paper, we review recent research articles on liquid-phase microextraction of drug substances from biological fluids, such as plasma, serum, urine, and saliva. We focus on papers where liquid-phase microextraction is combined with liquid chromatography coupled with mass spectrometry (LC-MS), published in the period 2019-2020. First, we discuss different configurations of liquid-phase microextraction, including dispersive liquid-liquid microextraction (DLLME), dispersive liquid-liquid microextraction based on solidified floating organic droplet (DLLME-SFO), single-drop microextraction (SDME), hollow-fibre liquid-phase microextraction (HF-LPME), solvent bar microextraction (SBME), and electromembrane extraction (EME). Second, we discuss new types of solvents used in liquid-phase microextraction, including ionic liquids, deep eutectic solvents, and nanostructured supramolecular solvents. Especially, we focus on the potential for implementation in routine laboratories, which we consider as the next step for liquid-phase microextraction.


Assuntos
Microextração em Fase Líquida , Preparações Farmacêuticas , Cromatografia Líquida , Espectrometria de Massas , Solventes
12.
Acta Vet Scand ; 62(1): 30, 2020 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-32546243

RESUMO

BACKGROUND: Exposure to anticoagulant rodenticides (ARs) in dogs is among the most common causes of poisoning in small animal practice, but information about toxicokinetic of these rodenticides in dogs is lacking. We analysed blood and faeces from five accidentally exposed dogs and 110 healthy dogs by reversed phase ultra-high performance liquid chromatography-tandem mass spectrometry. The aim of the study was to estimate elimination of brodifacoum, bromadiolone and difenacoum after acute exposure, calculate the half-lives of these rodenticides in dogs, estimate faecal elimination in a litter of puppies born, and further to identify the extent of AR exposure in a healthy dog population. RESULTS: Three dogs were included after single ingestions of brodifacoum; two dogs ingested bromadiolone and one dog ingested difenacoum. Maximum concentrations in faeces were found after day 2-3 for all ARs. The distribution half-lives were 1-10 days for brodifacoum, 1-2 days for bromadiolone and 10 days for difenacoum. Brodifacoum and difenacoum had estimated terminal half-lives of 200-330 days and 190 days, respectively. In contrast, bromadiolone had an estimated terminal half-life of 30 days. No clinical signs of poisoning or coagulopathy were observed in terminal elimination period. In blood, the terminal half-life of brodifacoum was estimated to 8 days. Faeces from a litter of puppies born from one of the poisoned dogs were examined, and measurable concentrations of brodifacoum were detected in all samples for at least 28 days after parturition. A cross-sectional study of 110 healthy domestic dogs was performed to estimate ARs exposure in a dog population. Difenacoum was detected in faeces of one dog. Blood and faecal samples from the remaining dogs were negative for all ARs. CONCLUSIONS: Based on the limited pharmacokinetic data from these dogs, our results suggest that ARs have a biphasic elimination in faeces using a two-compartment elimination kinetics model. We have shown that faecal analysis is suitable and reliable for the assessment of ARs exposure in dogs and a tool for estimating the AR half-lives. Half-lives of ARs could be a valuable indicator in the exposed dogs and provides important information for veterinarians monitoring AR exposure and assessment of treatment length in dogs.


Assuntos
Anticoagulantes/farmacocinética , Cães/metabolismo , Rodenticidas/farmacocinética , 4-Hidroxicumarinas/sangue , 4-Hidroxicumarinas/metabolismo , 4-Hidroxicumarinas/farmacocinética , Animais , Anticoagulantes/sangue , Anticoagulantes/metabolismo , Cromatografia Líquida de Alta Pressão/veterinária , Cães/sangue , Fezes/química , Espectrometria de Massas/veterinária , Rodenticidas/sangue , Rodenticidas/metabolismo
13.
Anal Chim Acta ; 1115: 23-32, 2020 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-32370866

RESUMO

Similarly to many other sample extraction techniques, efficient extraction of very polar compounds with electromembrane extraction (EME) is difficult. To date, the best known strategy to improve the mass transfer of these compounds is the addition of an ionic carrier, often bis(2-ethylhexyl) phosphate (DEHP) to the supported liquid membrane (SLM). DEHP is known to work by providing ionic interactions with basic compounds, to improve the partitioning into the SLM. In this work, the behavior of DEHP during extractions was studied for the first time. Interestingly, substantial amounts of DEHP was found to leak from the SLM into the aqueous sample at pH > 4. Due to this leakage, the ion-pair formation between analytes and DEHP was moved from the sample/SLM interface (interfacial complexation) to the bulk of the sample solution (bulk-sample complexation), which improved the mass transfer of polar bases considerably. Based on this, an extraction procedure for eight polar bases with log P values from +0.7 to -5.9 was developed and optimized. The optimization demonstrated that extraction of more polar analytes was favored by bulk-sample complexation. With optimized conditions, extraction from biological samples such as urine, protein-precipitated plasma, and raw plasma were performed with recoveries >40%, except for a few analytes. In addition, the extraction system could be operated under robust conditions with relatively low current (<70 µA for plasma), and provided low variability (<16% RSD), as well as good clean-up efficiency. These findings are an important step in further scientific anchoring of EME, and development of the technique towards selective extraction of very polar substances from complex biological matrices.


Assuntos
Técnicas Eletroquímicas , Organofosfatos/isolamento & purificação , Organofosfatos/química
14.
J Chromatogr A ; 1602: 117-123, 2019 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-31229251

RESUMO

The use of miniaturized systems with the possibility for automation has become increasingly popular in the field of bioanalysis. As a new approach to liquid phase microextraction in the 96-well format, parallel artificial liquid membrane extraction (PALME) was introduced in 2013. In the present work, the reliability of the quantitative data obtained with PALME was thoroughly evaluated. Amitriptyline, nortriptyline, quetiapine, venlafaxine, o-desmethylvenlafaxine, and fluoxetine were selected as model analytes. The analytes were extracted under non-exhaustive conditions from human plasma samples and the extracts were analyzed directly by LC-MS/MS. Accuracy was within ±15% and precision was <15% when the QC samples were prepared in both pooled plasma and in plasma from multiple sources. Accuracy and precision was superior when stable isotopically labelled (SIL) internal standards were used, as compared to structural analogue internal standards in the plasma samples from multiple sources. SIL internal standards are therefore recommended as the first choice. Assessment of accuracy and precision was also carried out with four different operators performing the extraction procedure, providing accuracy within ±15% and precision <15%. The extraction recoveries were in the range from 48 to 85 %, and non-exhaustive extraction of the analytes did not affect the accuracy and precision of the method. With the method described, up to 96 samples can be extracted with a total extraction time of 60 min and with a total consumption of organic solvent less than 0.4 mL for the whole wellplate. PALME is therefore a new approach to high-throughput sample preparation, providing accurate quantification, along with simple workflow, low consumption of organic solvent, and extensive sample clean-up.


Assuntos
Microextração em Fase Líquida/métodos , Preparações Farmacêuticas/sangue , Calibragem , Cromatografia Líquida , Humanos , Marcação por Isótopo , Membranas Artificiais , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
15.
J Wildl Dis ; 55(4): 834-843, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31112468

RESUMO

High occurrence of anticoagulant rodenticides (ARs) in wildlife is a rising concern, with numerous reports of secondary exposure through predation. Because of widespread distribution of the red fox (Vulpes vulpes), they may act as sentinels for small mammal-hunting predators in rural, suburban, and urban areas. No AR surveillance in wild mammals with analyses of residues in feces has been conducted throughout a single country. We collected 163 fecal samples from presumed healthy red foxes from 18 out of 19 counties in Norway. The foxes were shot during regular hunting between January and December 2016 and samples collected directly after death. Fecal samples were analyzed for six ARs: brodifacoum, bromadiolone, coumatetralyl, difenacoum, difethialone, and flocoumafen. We detected ARs in 54% (75/139) of the animals. Brodifacoum was most frequently detected (46%; 64/139), followed by coumatetralyl (17%; 23/139), bromadiolone (16%; 22/139), difenacoum (5%; 7/139), difethialone (1%; 2/139), and flocoumafen (1%; 2/139). More than one substance was detected in 40% (30/75) of the positive foxes, and 7% (5/75) of these animals were exposed to four different ARs. There were no statistically significant seasonal, age, or sex differences in foxes after exposure to one AR compound. We found a significant difference in occurrence of brodifacoum and coumatetralyl in foxes from different geographical areas. These findings demonstrate fecal analyses as a valuable method of detecting AR exposure in red foxes. We suggest using direct fecal sampling with analyses as a method to evaluate the occurrence of ARs in live endangered wildlife in connection with radio tagging or collaring operations.


Assuntos
Anticoagulantes/química , Fezes/química , Raposas , Rodenticidas/química , Animais , Exposição Ambiental , Monitoramento Ambiental , Poluentes Ambientais , Feminino , Cadeia Alimentar , Masculino , Noruega
16.
Eur Addict Res ; 25(2): 93-102, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30783038

RESUMO

BACKGROUND AND OBJECTIVES: Even though nightlife studies with potentially intoxicated participants provide the much needed information on drug use, they face additional methodological challenges. This study aimed to explore the utility of such studies by (i) classifying nightlife attendees based on their self-reported drug use and by (ii) examining whether these classifications were meaningful when assessed against other sources of data, including oral fluid drug tests. METHODS: Self-reported questionnaires, oral fluid samples and blood alcohol concentration readings were collected in a sample of 1,085 nightlife patrons recruited outside 12 popular nightclubs in Oslo, Norway, in 2014. Patrons were classified using multiple approaches, including latent class analysis. Group differences were examined by logistic regression models. RESULTS: Participants were classified into 5 mutually exclusive groups: 2 among current non-users ("Never-users"; "Previous users"), 2 among current users ("Multiple drugs"; "Cannabis mainly") and one "Incomplete information" group. Meaningful differences across these groups were observed. For instance, positive tests for any illicit drug were more common in "Multiple drugs" group than in "Cannabis mainly" (62.7 vs. 29.1%, adjusted OR [aOR] 3.77 [2.42-5.84]) or "Incomplete information" groups (62.7 vs. 34.4%, aOR 2.46 [1.26-4.79]). Despite their self-declared non-use, illicit substances were detected in oral fluids of "Never-users" (13.1%; 95% CI 9.9-17.2) and "Previous users" (7.9%; 95% CI 5.1-12.1). CONCLUSIONS: Despite some discrepancies between self-reports and biological tests, self-reports proved both suitable and useful in identification of substantively different drug-user typologies, potentially informing targeted policy responses. Still, methodological challenges associated with onsite studies of illicit drug use should be further explored.


Assuntos
Consumo de Bebidas Alcoólicas/metabolismo , Testes Respiratórios , Usuários de Drogas/estatística & dados numéricos , Atividades de Lazer , Saliva/metabolismo , Autorrelato , Detecção do Abuso de Substâncias , Adolescente , Adulto , Consumo de Bebidas Alcoólicas/sangue , Usuários de Drogas/classificação , Feminino , Humanos , Masculino , Noruega , Detecção do Abuso de Substâncias/métodos , Adulto Jovem
17.
J Pharmacol Exp Ther ; 368(1): 106-115, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30361238

RESUMO

Escalating opioid use among fertile women has increased the number of children being exposed to opioids during fetal life. Furthermore, accumulating evidence links prenatal opioid exposure, including opioid maintenance treatment, to long-term negative effects on cognition and behavior, and presses the need to explore novel treatment strategies for pregnant opioid users. The present study examined the potential of a monoclonal antibody (mAb) targeting heroin's first metabolite, 6-acetylmorphine (6-AM), in providing fetal protection against harmful effects of prenatal heroin exposure in mice. First, we examined anti-6-AM mAb's ability to block materno-fetal transfer of active metabolites after maternal heroin administration. Next, we studied whether maternal mAb pretreatment could prevent adverse effects in neonatal and adolescent offspring exposed to intrauterine heroin (3 × 1.05 mg/kg). Anti-6-AM mAb pretreatment of pregnant dams profoundly reduced the distribution of active heroin metabolites to the fetal brain. Furthermore, maternal mAb administration prevented hyperactivity and drug sensitization in adolescent female offspring prenatally exposed to heroin. Our findings demonstrate that passive immunization with a 6-AM-specific antibody during pregnancy provides fetal neuroprotection against heroin metabolites, and thereby prevents persistent adverse behavioral effects in the offspring. An immunotherapeutic approach to protect the fetus against long-term effects of prenatal drug exposure has not been reported previously, and should be further explored as prophylactic treatment of pregnant heroin users susceptible to relapse.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Heroína/efeitos adversos , Locomoção/efeitos dos fármacos , Derivados da Morfina/antagonistas & inibidores , Efeitos Tardios da Exposição Pré-Natal/induzido quimicamente , Efeitos Tardios da Exposição Pré-Natal/prevenção & controle , Analgésicos Opioides/administração & dosagem , Analgésicos Opioides/efeitos adversos , Animais , Animais Recém-Nascidos , Anticorpos Monoclonais/farmacologia , Feminino , Heroína/administração & dosagem , Locomoção/fisiologia , Camundongos , Camundongos Endogâmicos C57BL , Gravidez , Efeitos Tardios da Exposição Pré-Natal/psicologia , Distribuição Aleatória
18.
Anal Bioanal Chem ; 410(20): 4967-4978, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29947895

RESUMO

Benzodiazepines (BZD) and Z-hypnotics are frequently analyzed in forensic laboratories, and in 2012, the designer benzodiazepines (DBZD) emerged on the illegal drug scene. DBZD represent a particular challenge demanding new analytical methods. In this work, parallel artificial liquid membrane extraction (PALME) is used for sample preparation of DBZD, BZD, and Z-hypnotics in whole blood prior to UHPLC-MS/MS analysis. PALME of BZD, DBZD, and Z-hypnotics was performed from whole blood samples, and the analytes were extracted across a supported liquid membrane (SLM) and into an acceptor solution of dimethyl sulfoxide and 200 mM formic acid (75:25, v/v). The method was validated according to EMA guidelines. The method was linear throughout the calibration range (R2 > 0.99). Intra- and inter-day accuracy and precision, as well as matrix effects, were within the guideline limit of ± 15%. LOD and LLOQ ranged from 0.10 to 5.0 ng mL-1 and 3.2 to 160 ng mL-1, respectively. Extraction recoveries were reproducible and above 52%. The method was specific, and the analytes were stable in the PALME extracts for 4 and 10 days at 10 and - 20 °C. No carry-over was observed within the calibration range. PALME and UHPLC-MS/MS for the determination of DBZD, BZD, and Z-hypnotics in whole blood are a green and low-cost alternative that provides high sample throughput (96-well format), extensive sample clean-up, good sensitivity, and high reproducibility. The presented method is also the first method incorporating analysis of DBZD, BZD, and Z-hypnotics in whole blood in one efficient analysis. Graphical abstract.


Assuntos
Benzodiazepinas/sangue , Cromatografia Líquida de Alta Pressão/métodos , Drogas Desenhadas/análise , Hipnóticos e Sedativos/sangue , Membranas Artificiais , Espectrometria de Massas em Tandem/métodos , Benzodiazepinas/análise , Benzodiazepinas/isolamento & purificação , Cromatografia Líquida de Alta Pressão/economia , Drogas Desenhadas/isolamento & purificação , Desenho de Equipamento , Humanos , Hipnóticos e Sedativos/análise , Hipnóticos e Sedativos/isolamento & purificação , Limite de Detecção , Extração Líquido-Líquido/economia , Extração Líquido-Líquido/instrumentação , Espectrometria de Massas em Tandem/economia , Fatores de Tempo
19.
J Anal Toxicol ; 42(7): 446-458, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-29762694

RESUMO

Peripheral blood (PB) is considered to be the golden standard for measuring postmortem drug concentrations. In several cases, PB is however not available, but information regarding drug findings might still be crucial in order to determine the cause of death. Antidepressants are frequently detected in postmortem samples from forensic toxicology cases, but the literature investigating concentrations in other matrices than peripheral and heart blood is limited.We here describe a study for comparison of concentrations for a large number of different drugs in six different matrices. A total of 173 postmortem cases were included in the study material. The results from 44 cases with findings of antidepressants (amitriptyline/nortriptyline, citalopram, mianserin, mirtazapine, paroxetine, sertraline, trimipramine and venlafaxine) are presented in this article. Concentrations in peripheral and cardiac blood (CB), pericardial fluid (PF), two muscle samples and vitreous humour (VH) are compared. Ratios between concentrations in different matrices have also been compiled from available literature.All the investigated antidepressants were detected in all different matrices, and comparable concentration levels were found in the different matrices with a few exceptions. Concentrations in VH were generally lower than in the other matrices, and in a few cases with low concentrations in blood the antidepressants were not detected in VH. For most of the cases, ratios of 0.5-2 were found between concentration in PB and that in the other matrices. Some deviant concentrations where however found.This study shows that CB, PF, muscle and VH can provide important indications of the corresponding concentrations in PB when PB is not available.


Assuntos
Antidepressivos/análise , Músculo Esquelético/química , Líquido Pericárdico/química , Corpo Vítreo/química , Antidepressivos/sangue , Autopsia , Toxicologia Forense/métodos , Humanos , Mudanças Depois da Morte , Detecção do Abuso de Substâncias/métodos
20.
Anal Chim Acta ; 1009: 56-64, 2018 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-29422132

RESUMO

In this paper, parallel artificial liquid membrane extraction (PALME) was used for the first time to clean-up dried blood spots (DBS) prior to ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Fundamental studies exploring amongst others desorption from the DBS in alkaline or acidic aqueous conditions, total extraction time and absolute recoveries were executed. Desorption and PALME were performed using a set of two 96-well plates, one of them housing the sample and the other comprising the supported liquid membrane (SLM) and the acceptor solution. In one procedure, amitriptyline and quetiapine (basic model analytes) were desorbed from the DBS using 250 µL of 10 mM sodium hydroxide solution (aqueous), and subsequently extracted through the SLM consisting of 4 µL of 1% trioctylamine in dodecyl acetate, and further into an acceptor solution consisting of 50 µL of 20 mM formic acid. In a second procedure, ketoprofen, fenoprofen, flurbiprofen, and ibuprofen (acidic model analytes) were desorbed from the DBS into 20 mM formic acid, extracted through an SLM with dihexyl ether, and further into an acceptor solution of 25 mM ammonia. Within 60 min of PALME, both basic and acidic model analytes were effectively desorbed from the DBS and extracted into the acceptor solution, which was injected directly into the analytical instrument. Recoveries between 63 and 85% for the six model analytes were obtained. PALME provided excellent clean-up from the DBS samples, and acceptor solutions were free from phospholipids. Linearity was obtained with r2 > 0.99 for five of the six analytes. Accuracy, precision and UHPLC-MS/MS matrix effects were in accordance with the European Medicines Agency (EMA) guideline. Based on these experiments, PALME shows great potential for future processing of DBS in a short and simple way, and with the presented setup, up to 96 DBS can be processed within a total extraction time of 60 min.


Assuntos
Teste em Amostras de Sangue Seco , Extração Líquido-Líquido , Amitriptilina/sangue , Cromatografia Líquida de Alta Pressão , Fenoprofeno/sangue , Flurbiprofeno/sangue , Voluntários Saudáveis , Humanos , Ibuprofeno/sangue , Cetoprofeno/sangue , Membranas Artificiais , Fumarato de Quetiapina/sangue , Espectrometria de Massas em Tandem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...